GL6100 Power Supply
UK plug top style power supply for Airlink GL6100 GPRS modem.
UK plug top style power supply for Airlink GL6100 GPRS modem.
INPUT VOLTAGE: 100-240 VAC
INPUT CURRENT: < 0.6 A RMS MAX
INPUT FREQUENCY: 47 - 63 HZ
OUTPUT VOLTAGE: 12 VDC
OUTPUT CURRENT: 1.5A, NO MINIMUM LOAD REQUIRED TO MAINTAIN OUTPUT VOLTAGE
REGULATION
OUTPUT POWER (RATED): 18 WATTS MAX
OUTPUT REGULATION: +/- 5% MEASURED AT THE OUTPUT CONNECTOR
LINE VOLTAGE REGULATION: +/- 1% TYPICAL MEASURED AT FULL LOAD
OUTPUT RIPPLE (PEAK TO PEAK): 1% OR 150 mV WHICHEVER IS GREATER. MEASURED AT 20 MHz
BANDWIDTH WITH 0.1 μf CERAMIC CAPACITOR IN PARALLEL WITH 10 μf
ELECTROLYTIC CAPACITOR CONNECTED AT THE END
OF OUTPUT CONNECTOR AT NOMINAL LINE
TURN-ON/TURN-OFF OVERSHOOT: 5% MAXIMUM, 1mS TYPICAL RECOVERY TIME FOR 25% STEP LOAD
TURN-ON DELAY: 1 SECOND, TYPICAL
HOLD-UP TIME: 8mS TYPICAL AT NOMINAL INPUT VOLTAGE AND FULL LOAD
INRUSH CURRENT: 30A TYPICAL AT 115Vac INPUT AND 60A TYPICAL AT 230Vac INPUT
SWITCHING FREQUENCY: 65 KHz TYPICAL
PROTECTION
OVER-VOLTAGE: PROTECTED WITH ZENER CLAMP ACROSS OUTPUT
SHORT CIRCUIT: PROTECTED, UNIT WILL RECOVER UPON REMOVAL OF FAULT
INPUT PROTECTION: INPUT LINE FUSING
SAFETY
DIELECTRIC WITHSTAND VOLTAGE: 4242Vdc FROM PRIMARY TO SECONDARY
EARTH LEAKAGE CURRENT: <3.5 mA at 240Vac INPUT VOLTAGE
APPROVALS
SAFETY APPROVALS: UL60950-1, CUL TO 22.2#60950-1, INNOVA GS TO 60950-1,
CCC TO GB4943-2001, GB9254-1998, GB17625.1-2003,
CE CLASS I, AS/NZ 60950, PSE TO J60950, CB REPORT
EMI: COMPLIES WITH EN55022 CLASS B AND FCC PART 15 CLASS B, VCCI WHEN
TESTED WITH RESITIVE LOAD, BOTH CONDUCTED AND RADIATED EMI
CE MARK: TESTED TO COMPLY WITH EN61000-3-2 EN610003-3 AND EN50082-1
INCLUDING EN61000-4-2, EN61000-4-3, EN61000-4-4,
EN61000-4-5, EN61000-4-6, EN61000-4-11
C-TICK TESTED TO COMPLY WITH AUSTRALIA SECTION 182 OF
THE RADIO COMMUNICATION ACT OF 1992.
EFFICIENCY: COMPLIES TO SECTION 301 OF ENERGY INDEPENDENCE AND SECURITY ACT (EISA)
COMPLIES WITH ENERGY STAR TIER 2 (NORTH AMERICA),
CECP TIER 2 (CHINA), MEPS TIER 2 (AUSTRALIA), CODE OF CONDUCT (EUROPE)
OPERATING TEMPERATURE: 0°C TO 40°C AMBIENT TEMPERATURE
HUMIDITY: 0% TO 90% RELATIVE HUMIDITY
STORAGE TEMPERATURE: -10°C TO 80°C
ROHS: COMPLIES WITH EU 2002/95/EC AND CHINA SJ/T 11363-2006